Every structure leaves the works CE marked. Behind that mark are three factory production control certificates, all issued by Kiwa Inspecta — notified body 2268 — under the Construction Products Regulation 305/2011/EU, system 2+. Each is open-ended: it stays valid as long as the technical specification holds and the factory production control keeps meeting it.

Kiwa certificate 2268-CPR-434 for UAB Dr Verslas

Certificate No. 2268-CPR-434

EN 1090-3 — aluminium, EXC3

Aluminium structure elements and components for buildings and engineering structures. This is the certificate behind every aluminium bridge we deliver.

  • Execution classEXC3 to EN 1090-3
  • Welding process131 to EN ISO 4063
  • Material groups22.1, 22.2, 22.3, 22.4, 23.1
  • CE methods1, 3a
  • StandardEN 1090-1:2009+A1:2011
  • First issued14 July 2023

Download PDF

Kiwa certificate 2268-CPR-435 for UAB Dr Verslas

Certificate No. 2268-CPR-435

EN 1090-2 — steel, EXC2

Steel structure elements for buildings and engineering structures — for the parts of a project that are not aluminium: bearings, fixings, steel sub-structures.

  • Execution classEXC2 to EN 1090-2
  • Welding process135 to EN ISO 4063
  • Material groups1.1, 1.2, 1.4
  • CE methods1, 3a
  • StandardEN 1090-1:2009+A1:2011
  • First issued14 July 2023

Download PDF

Kiwa certificate 04-23-355 for UAB Dr Verslas

Certificate No. 04-23-355

LST EN ISO 17660-1

Welded inserts for reinforced concrete products — the welded connections cast into concrete abutments and foundations.

  • StandardLST EN ISO 17660-1:2006
  • System2+
  • First issued14 July 2023

Download PDF

Eurocode 9 is applied, not certified

The third badge in our header is Eurocode 9 — EN 1999, the European design standard for aluminium structures. It is not a certificate and no one issues one for it: it is the code the structure is calculated to. Structural calculations to Eurocode 9 go out with every quotation, together with the declaration of performance and the CE marking documentation. Our note on what Eurocode 9 covers explains what it governs and where it differs from the steel codes.

How to verify these before award

The certificate number and the notified body number are all a procurement officer needs. Kiwa publishes the validity of every certificate it issues at kiwa.com, and the notified body number 2268 can be checked in the European Commission NANDO database. Our note on how to check an EN 1090 certificate walks through the steps; what EN 1090 covers explains what the execution class actually changes in the workshop.

Certificate holder

UAB Dr Verslas
Reg. No. 302417821
Šiaurės g. 28, Didžiasalio k.
LT-13264 Vilniaus r., Lithuania

Manufacturing plant

Pramonės g. 22A, Meškonių k.
55196 Jonavos r. sav., Lithuania